HV Diagnostics TD30
Tan Delta Diagnostic Measurement System
Part Number
Included Options
Select Items To Quote
RENT/LEASE
BUY USED
HVD-TD30
Catalog Description
HV Diagnostics TD30
HVD-TD30
Tan Delta Diagnostic Measurement System
*Must be used with a HVA series of VLF systems!
**The
HVD-TD30
can be used with either the
HVD-HVA30
or the
HVD-HVA34
.
***Cannot be used with
HVD-HVA60
!
Tan Delta testing enables the cable test engineer to detect insulation defects
before the cablefails in service. The TD30 is a versatile tan delta measuring
system that is directly connected the HVA series of VLF test systems. The tan
delta of the test object can now be quickly measured and the results stored
thus providing a signature of the device being tested. This enables the cable
engineer to now make tan delta routine test.
Battery powered using 2 Alkaline "C" cells. Unit will operate for approx. 10
hours on fresh batteries.
Computer Interface: Wireless, Results download software is included
Output Voltage Sinusoidal: 1 - 23kV rms Frequency: 0.1 Hz
Voltage Measurement Resolution: 0.1kV rms Accuracy: 0.5% of reading
Current Measurement Resolution: 1uA rms Accuracy: 0.5% of reading
Frequency Measurement Resolution: 0.01 Hz
Tan Delta Measurement Resolution: 0.1 x 10-3 Accuracy: 0.2 x 10-3 (load >
40nF) 0.5 x 10-3 (load > 10nF)
Standards
Shock: IEC68-2-27 (15g/11ms half sinus)
Vibration: IEC68-2-6 (10..150Hz : 2g)
EMC: IEC6100-4-2, IEC6100-4-4, EN55011
Safety: EN60950, EN50191, EN61010-1
Length
Width
Height
Ship Wt
24.13 cm
8.13 cm
0 cm
15.91 kg
Need Configuration Assistance? Call our experienced Sales Staff.